Military  

As a veteran owned company Radiometrics has excelled as a Military EMC facility. Tests have been performed for all military branches both domestic and international. The demands of high level engineering expertise are always met. Our NARTE certified engineers are present for all testing and mitigation. Military EMC testing is also within our scope of accreditation from A2LA.

 

MIL-STD 461/462

CE101

Conducted Emissions, power leads 30 Hz to 10 kHz

CE102

Conducted Emissions, power leads 10 kHz to 10 MHz

CE106

Conducted Emissions, antenna terminals 10 kHz to 40 GHz

CS101

Conducted Susceptibility, power leads 30 Hz to 50 kHz

CS103

Conducted Susceptibility, antenna port, intermodulation,

15 kHz to 10 GHz

CS104

Conducted Susceptibility, antenna ports, rejection of undesired signal, 30 Hz to 20 GHz

CS105

Conducted Susceptibility, antenna ports, cross modulation,

30 Hz to 20 GHz

CS109

Conducted Susceptibility, structural current, 60 Hz to 100 kHz

CS114

Conducted Susceptibility, bulk cable injection, 10 kHz to 400 MHz

CS115

Conducted Susceptibility, bulk cable injection, impulse excitation

CS116

Conducted Susceptibility, damped sinusoidal transient,

cable and power leads, 10 kHz to 100 MHz

RE101

Radiated Emissions, magnetic fields 30 Hz to 100 kHz

RE102

Radiated Emissions, electric fields 10 kHz to 18 GHz

RE103

Radiated Emissions, antenna spurious and harmonics,

10 kGHz to 40 GHz

RS101

Radiated Susceptibility, magnetic fields 30 Hz to 100 kHz

RS103

Radiated Susceptibility, electric fields 10 kHz to 40 GHz

RS105

Radiated Susceptibility, transient electromagnetic fields

MINISTRY OF DEFENCE, DEFENCE STANDARD 59-41

DCE01

Conducted Emissions on Primary Power Lines, 20 Hz – 150 MHz

DCE02

Conducted Emissions on Control, Signal and Power Lines,

20 Hz to 150 MHz

DCE03

Export Transients, Primary Power Lines

DCS01

Conducted Susceptibility, Primary Power Lines, 20 Hz to 50 kHz

DCS02

Conducted Susceptibility, Power, Control and Signal Lines,

50 kHz 400 MHz

DCS03

Conducted Susceptibility, Control and Signal, 20 Hz – 50 kHz

DCS04

Conducted Susceptibility, Imported Transient Susceptibility (Aircraft)

DCS05

Conducted Susceptibility, Externally Generated Transients (Land and Sea Systems)

DCS06

Conducted Susceptibility, Imported Long Transient susceptibility (Land and Sea Services), AC and DC Systems

DCS08

Conducted Susceptibility, Externally Generated Transients (Aircraft)

DCS09

Conducted Susceptibility, Imported Lightning Transient Susceptibility (Aircraft)

DCS10

Conducted Susceptibility, Electrostatic Discharge (ESD)

DCS12

Conducted Susceptibility, Imported Low Frequency Transient Susceptibility – Power Lines (Sea Systems)

DRE01

Electric (E) Field Radiated Emissions, 14 kHz to 18 GHz

DRE02

Magnetic (H) Field Radiated Emissions, 20 Hz to 100 kHz

DRE03

Radiated Emissions Installed Antenna, 1.6 MHz to 76 MHz

DRS01

Magnetic (H) Field Susceptibility, 20 Hz to 100 kHz

DRS02

Electric (E) Field Susceptibility, Standard Method,

10 kHz to 18 GHz

DRS03

Magnetic Field (DC) Susceptibility, Land and Sea Systems

 

 